Translations of this page:

Siemens MC35 logs

DELIVER_REPORT Example

07911326040000F0200B911356371785F60000800103317023402454747A0E4ACF41EE77AB5D6E8BCBF2F90934A787DDE4B09C0C6A97E7F3F0B90C<LF>

Testing incoming sms indication and read sms


Welcome to minicom 2.00.0

OPTIONS: History Buffer, F-key Macros, Search History Buffer, I18n
Compiled on Feb 21 2005, 19:32:30.

Press CTRL-A Z for help on special keys

AT S7=45 S0=0 L1 V1 X4 &c1 E1 Q0
OK
AT+CSDH=?
+CSDH: (0,1)

OK

RING
AT+CNMI=?
+CNMI: (0-3),(0,1),(0,2,3),(0,2),(1)

OK
AT+CNMI=?
+CNMI: (0-3),(0,1),(0,2,3),(0,2),(1)

OK
AT+CNMI=2
OK
AT+CNMI=2,3,0,2
ERROR
at
OK
AT+CNMI=2,3,0,2
+CMS ERROR: 500
AT+CNMI=?
+CNMI: (0-3),(0,1),(0,2,3),(0,2),(1)

OK
AT+CNMI=2,1,0,2
OK

+CMTI: "MT",8
AT+CMGR=8
+CMGR: 0,,72
07911326040000F0240B911326216246F40000906011613094803CF4F29C0E6A97E7F3F0B9DC50CC

OK
AT+CMGF=1
OK
AT+CMGR=8
+CMGR: "REC READ","+31621226644",,"09/06/11,16:03:49+08"
test message
sent to test if there will be event on receive

OK
AT+CNMI=
OK

+CMTI: "MT",9
AT+CMGR=9
+CMGR: "REC UNREAD","+31621226644",,"09/06/11,17:10:56+08"
test message
sent to test if there will be event on receive

OK
AT+CMGR=9
+CMGR: "REC READ","+31621226644",,"09/06/11,17:10:56+08"
test message
sent to test if there will be event on receive

OK

 
lcb/programming/siemens-mc35/logs.txt · Last modified: 06.22.2009 13:53 by npelov
 